This page is intended to inform cleanroom users of activities which may affect cleanroom use as well as indicating cleanroom environmental parameters.
All cleanroom data updated as of:
July 6, 2004 11:26
- Cleanroom Status: Operational
- Air changes per hour: 100
- Cleanroom temperature: 19.50°C
- Cleanroom Humidity: 50.14%
- NVR level classification (MIL-STD 1246):Level A5
- Particle fallout classification (MIL-STD 1246): Level 106.6 (avg)
- Cleanroom classification (ISO ):Class 100
- Airborne molecular contamination rate: 2Å/month
Short and medium term service activities for cleanroom:
- 22 Sep 2004 - Six monthly service and validation. Cleanroom will be out of action for the day.Recommend all sensitive hardware be draped/covered. Assembly activities should not take place over this period.
27th & 28th April 2004 - Cleanroom antroom floor replacement. No access to cleanroom for these two days as Dycem lay a new workzone cleanroom floor in the anteroom.
21 Apr 2004 - Six monthly service and validation. Cleanroom will be out of action for the day.Recommend all sensitive hardware be draped/covered. Assembly activities should not take place over this period.
24 Feb 2004 - Cleanroom humidity and temperature controls remedial work, including condensor units - Cleanroom will be out of action for the day.Recommend all sensitive hardware be draped/covered. Assembly activities should not take place over this period.
16 Feb 2004 to 18 Feb 2004 - Installation of chiller water supply pipes for laser facility. Activity will last 2 days. Recommend all sensitive hardware be draped/covered. Assembly activities should not take place over this period.